Sable Grid Storage Business Plan — Operations, Maintenance & Asset Management

Operations are deliberately lean. The long-term service agreement transfers preventive and corrective maintenance, spares and augmentation to the…

Operations, Maintenance & Asset Management

Jump to section

Operations are deliberately lean. The long-term service agreement transfers preventive and corrective maintenance, spares and augmentation to the technology partner against availability guarantees. Sable retains asset management: contract administration, dispatch compliance, revenue metering, insurance, health and safety oversight and owner’s engineering. A twenty-four-hour remote operations centre in Sandton monitors the facility, with two site-based technicians and contracted security maintaining physical presence at Aggeneys.

13.1 Organisation at steady state

Figure 12. Organisation at steady state, 19 permanent roles.

Function

Headcount

Notes

Executive (CEO, CFO, CTO)

3

Shared across the Company and the pipeline

Asset management & commercial

4

Contracts, billing, market operations, compliance

Remote operations centre

5

Shift coverage, dispatch interface, performance analysis

Site operations (Aggeneys)

2

Local technicians recruited from host communities

Finance & administration

3

Reporting, treasury, payroll, company secretarial

Community & ESG

2

Trust liaison, social performance, grievance management

Total

19

Excludes contracted security and LTSA personnel

13.2 Operating cost base

Figure 13. Year-1 operating cost base of R52 million.

R million

Year 1

Year 5

Year 10

Year 15

LTSA & O&M

28

34

43

55

Insurance

9

11

14

18

Staff & admin

11

13

17

22

Land & rates

4

5

6

8

Total operating costs

52

63

81

103

At R52 million against R396 million of revenue, the operating cost base is approximately 13% of turnover, the defining economic characteristic of availability infrastructure. There is no fuel, no significant variable cost and minimal labour. The long-term service agreement accounts for more than half of the total and is a contracted, escalating obligation rather than a managed cost, which limits both the downside risk and the scope for operational improvement. Cost discipline matters far less to this business than availability and contract administration.

13.3 Health, safety and environment

The Company operates to Occupational Health and Safety Act requirements and NFPA 855-aligned battery safety standards, with cell-level thermal monitoring, off-gas detection and emergency response protocols agreed with the district fire service. Environmental commitments arising from the basic assessment are tracked in a compliance register audited annually. For a lithium-ion facility, fire and thermal-runaway management is the dominant safety consideration, and the combination of lithium iron phosphate chemistry, which is markedly more thermally stable than nickel-based alternatives, with cell-level monitoring, deflagration venting and standards-aligned container spacing represents current best practice.